Fiberglass batt 3 14 fiberglass blown attic 2 20 1 fiberglass blown wall 3 20 rock wool batt 3 14 rock wool blown attic 3 10 rock wool blown wall 3 03 cellulose blown attic 3 13 cellulose blown wall 3 70 vermiculite 2 13 air entrained concrete 3 90 urea terpolymer foam 4 48 rigid fiberglass 4 lb ft3 4 00 expanded polystyrene bead board 4 00 extruded polystyrene 5 00 polyurethane.
R value of attic air space.
Our r value cognitive dissonance.
You can achieve better thermal performance in your attic by adding an additional layer of insulation.
The total insulation r value for the assembly will be an r 39 r 20 r 19 which complies with the prescriptive requirements of the 2009 iecc.
The higher the r value the better the thermal performance of the insulation.
Air gaps larger than this work well too they promote ventilation on the foil and help keep the air dry and the air temps lower.
Remember the horizontal or vertical orientation of the material is important to get its insulation value correct.
Cathedral ceiling above mass insulation r 6 summer r 2 winter 2200 series double sided reflective insulation.
Doesn t insulation count as an air space.
Work out all the different materials and surfaces that make up the wall ceiling or surface you want to work out the r values and u values for.
Insulation is technically a solid with a lot of air in it therefore.
What i m talking about is a house with ducts in unconditioned space especially an unconditioned attic.
Existing 3 4 inches of insulation.
Typically we suggest you have an air gap between 1 2 and 3 4 for the radiant barrier to work.
If we put ducts in unconditioned space they have to be insulated to either r 8 if they re in an unconditioned attic or r 6 in any other type of unconditioned space.
Applications air space requirements.
Achieving greater r values in exterior walls.
The r value calculator is best used as follows.
I m in georgia iecc climate zone 3 where our current state code requires r 13 in exterior walls r 18 in attic kneewalls r 19 in floors and r 30 in ceilings.
Installed on bottom of rafters or directly to inside of roof deck.
Fibers from rock or recycled slag from blast furnaces.
Recommended insulation levels for retrofitting existing wood framed buildings.
Material r inch r thick ness insulation materials.
R value of building materials.
The irc also prohibits a vapor retarder on the attic floor of conditioned attics so that any moisture that may build up in the attic can dissipate into the house.
1 and 6 the r value of a non reflective air space and vinyl siding provides an r value of about r 0 64.
The most common blown in material used but it can rot and grow moldy if exposed to moisture.