These are only to be used as accessories to a fire or combined fire burglar alarm system.
Rate of rise heat detector attic.
The pneumatic element responds to a rapid rise in temperature approximately 15ºf 8ºc per minute when the air expands faster within the sealed chamber than it can escape through the calibrated vent.
The rate of rise sensor detects a rapid rise in temperature and signals an alarm if the rise is 15 f 8 c or more per minute.
Treated with the powerful rate of rise and fixed rate technology.
Features alarm latch to easily identify initiating alarm.
This is a continuation on the series of articles about the most important requirements in nfpa 72 national fire alarm code book.
Rate of rise thermal detectors measure the rate at which the air temperature changes during a fire event.
The 5809ss combines a rate of rise sensor and a fixed temperature sensor in one device.
The kidde hd135 f is inter connectable.
Rate of rise units have a wide spacing allowance of 50 foot centers.
The rate of rise function detects heat quickly by responding to a rapid temperature increase.
The rate of rise test should be conducted by a qualified fire protection specialist using a 1 000 watt heat gun or hair dryer.
Alarm is audible up to a distance of 10 ft.
Measuring the change in temperature provides a faster alarm response than measuring the temperature level in a space.
Btw there is one system sensor brand we sell online smoke detector that is designed for dusty environments.
Nfpa 72 chapter 5 initiating devices heat detectors.
The 120 volt hardwired heat alarm detects heat at 135 f with its microprocessor temperature sensor.
The 5809ss rate of rise thermostat senses the rise in temperature and signals an alarm if the increase is 15 f or more per minute.
Under normal ambient conditions with an air velocity at the detector of 400 feet per minute or less the detector s contacts should close within 10 seconds when the heat gun nozzle is located approximately 6 inches from the detector.
Heat detectors are available in 135 f and 200 f temperature ratings.
The interconnect system must not exceed the nfpa national fire protection association limit of 18 initiating devices smoke heat co etc interconnected it is still possible to interconnect 6 strobe lights and or relay modules.
The 5809 series is ul listed ul 521 and csfm approved for commercial and residential applications.
The series 600 heat detector is attractive durable and features combination rate of rise and fixed temperature operation.
Rate of rise detects heat by quickly responding to a rapid temperature increase.
They are not life safety devices though.